Panneau General information on our panels with leds

While clicking on the image opposite, reach directly all general information on our panels with leds.


J3500
J3500 Software
J3500
Format DIN 144x144.

Automat of centralization of technical defaults to 12 leds high luminosity with parameter setting PC and display of text.

The "top-of-the-range" which takes again the functionalities of J3000 with the flexibility of programming PC. Many additive functions.

Use: All industries including industry "at the risk". To choose preferably in the situations asking a thorough and different parameter setting, way by way.

Simple and convivial PC software included.

Selections by ways:
- 12 inputs "contacts" normaly open or normaly close.
- Temporization of the inputs of 20ms with 23h.
- Blocking, Inhibition, Put in disturbance of the way.
- Wire Control of continuity on each entry.
- Association of 4 possible outputs per input.

Management of the outputs :
- possible positive Safety on each outputs.
- Activation dependent on the input, the memory, according to the state of the indicator, at fault 1st on many alarms.
- Outputs in synthesis possible select.

Management and treatment of alarms and indications:
- Selection of the way out of alarm or simple indication.
- Types of multiple sequences of blinking.
- Revival of setting alarm.
- Reactivation depending on the state of the input.
- Acknowledge or by way.
- Possible Blocking of the buttons of frontage.
- Button of frontage with distant report.

Display of text:
- Possible Parameter setting by button and display of text.
- Display of the history of the events.
- Display of particular alarms.
- 3 possible languages.

Supplies :
- Supply continus or alternative.
- Possible supply : 14Vdc-65Vdc, 14Vac-49Vac, 80Vac/dc-260 Vac/dc.
- Permanent Control of supply (mini and max).

Option :
- Inputs / Outputs Bus RS422 / RS485, Modbus, Jbus.

pdf Data sheet blanc pdf Starting data sheet notice pdf accessories


J3000 J3000
Format DIN 144x144.

Automats of treatment of technical defaults to 12 leds high luminosity, settings by switchs.

Agreement Veritas.
Use: All industries including industry "at the risk".

Selections by ways:
- 12 inputs "contacts" normaly open or normaly close.
- 12 leds 10x10mm.
- 12 outputs "open collector" or possible "contact".
- Fixed indicator or blinking.
- Memorizing of alarms.
- Acknowledge by integrated button and/or reported.
- Sequence of 1st defect to 5ms.
- Selection "alarms" or "simple indication" by way.
- Wire Control of continuity on each input.
- Possible Temporization of the inputs.
- Automatic Revival of alarms possible.
- Output "general alarm" .

Option :
- Inputs / Outputs Bus RS485.
- Version blind case (station of blinking) possible.

 Data sheet notice pdf accessories


J1900 J1900
Format DIN 96x96.

Treatment panel of alarms sequence to 8 leds high luminosity.

Principal use: TERTIARY SECTOR.

Selections ways by ways :
- 8 entries "contacts" normaly open or normaly close.
- 8 outputs "open collector", possible outputs "contact".
- 8 leds 5x10mm.
- fixed indicator or blinking (with sequence of alarm).
- possible Blocking of the input by ways.
- Temporization of each input.
- Relay "general alarm" possible select.

Option :
- Buzzer.

For installations comprising several J1900 panels, defer to the ALARM' BOX.

pdf Data sheet notice pdf accessories